ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 北陸学院短期大学紀要
  2. 第35号

A Study on Depth Perception in Reversed Vision(V) : An Experiment on Binocular Stereopsis with an Inverting Stereoscope

https://hokurikugakuin.repo.nii.ac.jp/records/418
https://hokurikugakuin.repo.nii.ac.jp/records/418
ff05be0f-555b-46bb-8f8d-88145863c02e
名前 / ファイル ライセンス アクション
35-22 35-22 ohta (755.8 kB)
license.icon
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2016-08-25
タイトル
タイトル A Study on Depth Perception in Reversed Vision(V) : An Experiment on Binocular Stereopsis with an Inverting Stereoscope
タイトル
タイトル A Study on Depth Perception in Reversed Vision(V) : An Experiment on Binocular Stereopsis with an Inverting Stereoscope
言語 en
言語
言語 jpn
キーワード
主題Scheme Other
主題 inverting stereoscope
キーワード
主題Scheme Other
主題 binocular stereopsis
キーワード
主題Scheme Other
主題 optic chiasma
キーワード
主題Scheme Other
主題 binocular parallax
キーワード
主題Scheme Other
主題 binocular convergence
キーワード
言語 en
主題Scheme Other
主題 inverting stereoscope
キーワード
言語 en
主題Scheme Other
主題 binocular stereopsis
キーワード
言語 en
主題Scheme Other
主題 optic chiasma
キーワード
言語 en
主題Scheme Other
主題 binocular parallax
キーワード
言語 en
主題Scheme Other
主題 binocular convergence
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
著者 太田, 雅夫

× 太田, 雅夫

WEKO 533

太田, 雅夫

Search repository
Ohta, Masao

× Ohta, Masao

WEKO 534

en Ohta, Masao

Search repository
抄録
内容記述タイプ Abstract
内容記述 The purpose of this experiment was to prove the hypothesis that when both eyes are turned 180 degrees at the center of the distance between them, the visual fields of both eyes would be turned over, but normal stereoscopic vision of the reversed image would be obtained by binocular parallax, while maintaining binocular convergence. It was thought that if this was proved, the fundamental supposition that both eyes are rotated entailing optic chiasma, so the retinal images turned over by each lens are reversed, and then an upright retinal image with normal stereoscopic vision can be obtained, would be supported functionally. The inverting stereoscope was designed to make reversed figures by the rotation of two video cameras and to reflect the figure on each of two liquid crystal screens. The hypothesis was proved from the result of this experiment on the depth perception of stereograms and real materials, and so the supposition was supported.
内容記述
内容記述タイプ Other
内容記述 The purpose of this experiment was to prove the hypothesis that when both eyes are turned 180 degrees at the center of the distance between them, the visual fields of both eyes would be turned over, but normal stereoscopic vision of the reversed image would be obtained by binocular parallax, while maintaining binocular convergence. It was thought that if this was proved, the fundamental supposition that both eyes are rotated entailing optic chiasma, so the retinal images turned over by each lens are reversed, and then an upright retinal image with normal stereoscopic vision can be obtained, would be supported functionally. The inverting stereoscope was designed to make reversed figures by the rotation of two video cameras and to reflect the figure on each of two liquid crystal screens. The hypothesis was proved from the result of this experiment on the depth perception of stereograms and real materials, and so the supposition was supported.
書誌情報 北陸学院短期大学紀要
en : Bulletin of Hokuriku Gakuin Junior College

巻 35, p. 287-297, 発行日 2004-03-05
出版者
出版者 北陸学院短期大学
ISSN
収録物識別子タイプ ISSN
収録物識別子 02882795
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00227546
論文ID(NAID)
識別子タイプ NAID
関連識別子 110004782958
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 08:39:12.336573
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3